GE LUNAR Prodigy Bone Densitometer
Specifications
Available Applications and Options
- AP Spine, Femur Dual, Femur Advance Hip Assessment with Hip Axis Length, Cross Sectional Moment of Inertia and Femur Strength Index Total Body*
- Body Composition* (with fat/lean assessment) Dual Energy Vertebral Assessment (DVA) Forearm Lateral Spine BMD
- Orthopedic Hip Analysis Pediatric*?Infant Total Body*** Small Animal
- One Vision, One Scan, Composer with 10-year Fracture Risk assessment Practice Management Report Dexter PDA interface software** Computer Assisted Densitometry (CAD) Tele Densitometry**?DICOM (Worklist – Color Print and Store)**?Multi User Data Base Access (3/10)**HL7 Bidirectional interface **
Software Platform
- Advanced intuitive graphical interface, Multiple Patient directories with Microsoft Access® database, Smart Fan TM for scan window optimization and dose reduction? Automated Scan mode selection ?Auto Analysis TM for a better precision
- Customized Analysis for clinical flexibility? Exam Comparison process? BMD or s BMD results (BMC and Area)?Extensive Reference Data
- > 12,000 subjects – NHANES and several Regional Lunar Reference Data User defined Reference Population
- T-score, Z-score, % Young-Adults and % Age-Match Automated WHO Background evaluation Patient trending with previous exam importation Multiple languages available
- Multimedia Online Help
Typical Scan Time and Radiation Dose at the best Precision
- AP Spine : 30 sec : 0.037mGy (< 1%CV)?Femur : 30 sec : 0.037 mGy (< 1%CV)?Total Body/ Body Comp. : 4 min 30sec: 0.0003 mGy (< 1%CV)
Calibration and Quality Assurance
- Automated test program with complete mechanicals and electronics tests and global measurement calibration Automated QA Trending with complete storage
Scanning Method
- Narrow Fan Beam (4,5° angle) with Smart Fan, MVIR and Tru View algorithms
X-ray characteristics
- Constant potential source at 76kV Dose efficient K-edge filter
Detector technology
- Direct-Digital CZT (Cadmium Zinc Telluride) detector Energy sensitive solid state Array
Magnification
- None – Object-plane measured
Dimensions (L x H x W) and weight
- 263 x 111 x 128 cm – 272 kg (Full)?202 x 111 x 128 cm – 254 kg (Compact) Vinyl table pad
External shielding
- Not required : X-ray safety requirements may vary upon destination.
Environnemental requirements
- Ambient temperature: 18-27°C?Power: 230/240 VAC ±10%, 10A, 50/60 Hz Humidity: 20% – 80%, non-condensing
Computer workstation
- Windows XP® Professional Intel processor computer, printer and monitor