GE LUNAR Prodigy Bone Densitometer

2.7 out of 5 based on 125 customer ratings

Specifications

Available Applications and Options

  • AP Spine, Femur Dual, Femur Advance Hip Assessment with Hip Axis Length, Cross Sectional Moment of Inertia and Femur Strength Index Total Body*
  • Body Composition* (with fat/lean assessment) Dual Energy Vertebral Assessment (DVA) Forearm Lateral Spine BMD
  • Orthopedic Hip Analysis Pediatric*?Infant Total Body*** Small Animal
  • One Vision, One Scan, Composer with 10-year Fracture Risk assessment Practice Management Report Dexter PDA interface software** Computer Assisted Densitometry (CAD) Tele Densitometry**?DICOM (Worklist – Color Print and Store)**?Multi User Data Base Access (3/10)**HL7 Bidirectional interface **

Software Platform

  • Advanced intuitive graphical interface, Multiple Patient directories with Microsoft Access® database, Smart Fan TM for scan window optimization and dose reduction? Automated Scan mode selection ?Auto Analysis TM for a better precision
  • Customized Analysis for clinical flexibility? Exam Comparison process? BMD or s BMD results (BMC and Area)?Extensive Reference Data
  • > 12,000 subjects – NHANES and several Regional Lunar Reference Data User defined Reference Population
  • T-score, Z-score, % Young-Adults and % Age-Match Automated WHO Background evaluation Patient trending with previous exam importation Multiple languages available
  • Multimedia Online Help

Typical Scan Time and Radiation Dose at the best Precision

  • AP Spine : 30 sec : 0.037mGy (< 1%CV)?Femur : 30 sec : 0.037 mGy (< 1%CV)?Total Body/ Body Comp. : 4 min 30sec: 0.0003 mGy (< 1%CV)

Calibration and Quality Assurance

  • Automated test program with complete mechanicals and electronics tests and global measurement calibration Automated QA Trending with complete storage

Scanning Method

  • Narrow Fan Beam (4,5° angle) with Smart Fan, MVIR and Tru View algorithms

X-ray characteristics

  • Constant potential source at 76kV Dose efficient K-edge filter

Detector technology

  • Direct-Digital CZT (Cadmium Zinc Telluride) detector Energy sensitive solid state Array

Magnification

  • None – Object-plane measured

Dimensions (L x H x W) and weight

  • 263 x 111 x 128 cm – 272 kg (Full)?202 x 111 x 128 cm – 254 kg (Compact) Vinyl table pad

External shielding

  • Not required : X-ray safety requirements may vary upon destination.

Environnemental requirements

  • Ambient temperature: 18-27°C?Power: 230/240 VAC ±10%, 10A, 50/60 Hz Humidity: 20% – 80%, non-condensing

Computer workstation

  • Windows XP® Professional Intel processor computer, printer and monitor

 

Product Description

123