Lorad M-IV Platinum Mammography

2.62 out of 5 based on 318 customer ratings

Bi-angular X-ray Tube

 

  • Custom design with high speed anode rotation
  • significantly higher mA loading and output
  • Maintain tight focal spot size tolerances
  • Eliminate the need to wait for the tube to cool down
  • Receive exceptionally high quality, high resolution images for both full field and magnification viewsFAST Paddle
  • Fully Automatic Self-Adjusting Tilt (FAST) Paddle
  • Improve imaging
  • Provide greater patient comfort
  • Ensure more uniform compression across the entire breast
  • Superior image quality
  • Improve immobilization of breast tissue
  • Reduce motion artifacts
  • Prevent loss of compression or over-compression at the chest wall
  • Enhance patient comfort and optimal imagingAdvanced Solutions For Breast Imaging
  • Offer a full compliment of diagnostic accessories
  • Obtain flexibility and functionality essential for the diagnostic evaluation of an area of interest
  • Quickly convert the M-IV to an advanced imaging system for stereotactic, needle localization and ultrasound procedures with specialized accessories
  • Perform exams while under compression
  • Visualize the breast tissue in the same plane as the mammogram
  • Increase diagnostic assurance without any inconvenience to your patients

         Ease Of Operation

 

  • Advanced automated features
  • Get outstanding consistency and operator efficiency
  • AutoFilter
  • Conveniently select appropriate exposure and filtration settings
  • Automatic Collimation Complete
  • Eliminate manual apertures
  • Four Exposure Modes
  • From fully automatic to totally operator-selected, based on operator preference
  • Operator Preferences
  • Store and automatically activate upon log-inImage Quality
  • Capture high quality images
  • High Transmission Cellular Grid (HTC Grid)
  • Get higher contrast images
  • Bi-angular X-ray Tube
  • Enhance magnification views with a custom designed high performance tube
  • FAST Paddle
  • Exclusive Fully Automatic Self-adjusting Tilt Paddle
  • Achieve more uniform compression
  • 3-Cell, 7 Position AEC Sensor
  • Unique Automatic Exposure
  • Control for more precise technique selection

Gantry:

Height: 75 in
Width: 25 in
Depth: 50 in

Weight: 850 lbs

Console With Lead Glass Shield:

Height: 74 in
Width: 32 in
Depth: 17 in

Weight: 250 lbs

Generator

High frequency constant potential

Ma range (IMAGING SYSTEM)
30, 100

Kv range (X-RAY GENERATOR) 20increments of 1 kV

mAs RANGE (X-RAY TUBE) 3

Power Needed

200-240 VAC 10%, 35 A, 50/60 Hz2

 

 

Category:

Product Description

fe08fc2d6fdeea67c0aaf9578800205a